WEKO3
アイテム
女子長距離走選手の頚動脈圧受容器一心臓圧反射応答
https://kyukyo.repo.nii.ac.jp/records/192
https://kyukyo.repo.nii.ac.jp/records/19293e81d0a-658f-44f5-a852-442bd4ef69f0
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-06-28 | |||||
タイトル | ||||||
タイトル | 女子長距離走選手の頚動脈圧受容器一心臓圧反射応答 | |||||
タイトル | ||||||
タイトル | Carotid baroreceptor-cardiac responsiveness in female long distance runners | |||||
言語 | en | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | endurance trained athletes | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | carotid baroreceptors | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | neck chamber | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | baroreflex sensitivity | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者 |
佐川, 壽榮子
× 佐川, 壽榮子× 森川, 壽人× Sagawa, Sueko× Morikawa, Hisatoshi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | There are evidences suggesting that endurance-trained athletes (ET) fail to maintain blood pressure responses to gravitational challenges such as head-up tilt, standing, or lower body negative pressure. The purpose of the present study was to examine whether gravitational intolerance in ET was due to a blunted carotid baroreceptor cardiac responsiveness. Eight ET females (long distance runners, 18.4±0.2 y.o.) and seven endurance-untrained females (UT 20.4±0.9 y.o.) participated in the experiment. Carotid baroreceptor-cardiac responses were estimated by using a neck chamber. R-R intervals were plotted against carotiddistending pressures and the response was analyzed by applying a four-parameter sigmoidal logistic function. The maximal gain of the curve in ET group was greater (P<0.05) than that of UT group, indicating increased baroreflex sensitivity. The centering point of the curve, an indicator of the operating point, was identical. There was a significant correlation between maximal 02 consumption and maximal gain (r=0.693, P<0.005). These results may suggest that attenuated baroreflex control of the heart rate in ET is not responsible for the mechanisms of the gravitational intolerance. |
|||||
書誌情報 |
九州共立大学スポーツ学部研究紀要 en : Bulletin of Kyushu Kyoritsu University. Faculty of sports science 号 3, p. 7-11, 発行日 2009-03-31 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1881848X | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12208489 |